Proscenium Opening: Height:30’   Width: 57’ - 6”

Stage Depth:

Edge of stage to back wall: 36’

Curtain line to back wall:    30’

Stage Width:

Wall to wall is 80’ at widest point.  There is a jog in the stage left wall; see floor plan. Center stage to either wall is 40’

Pin Rail:

Located on Stage Right.

Orchestra Pit:     

12’ x 40’; motorized (screw jack lifts). 

May be used at any level from stage level to 7’ below the stage.

Electrical Service:

Lighting:

Lighting:

Sound:

Three Services:

220v-600 amps     3 phase down stage right

220v-400 amps     3 phase back wall up stage right

220v-200 amps     3 phase down stage right    

All services are fuse protected. Dimmer racks that are brought in should be located down stage right on deck in alcove.

Follow Spots:

2 Xenon Super Troopers

1 Orbiter Long Throw       

Projection Booth:

Distance:

Power:   

Located behind balcony.  There is room in the booth for a maximum of four spots.  

155’ throw from booth to curtain line.

2 single phase, 30 amp breakers

Front of House Positions:

    Balcony Rail:             

   

    FOH Box Booms:

35’ wide pipe

Distance - 53’ to proscenium. 

No available transfer circuits.

Located Stage Left and Right in Balcony Loge.

Fly System:

Single Purchase Counterweight

7470 pounds available.

38 line sets at 7” on center with 5 lift lines per set.

Arbors are 500 to 1,000 lb capacity (see line set schedule)

Pipes are 64’ long with 53’ travel from the deck.

2 block and falls available-2:1

Permanent Installations:  

(Dimensions from smoke pocket)

House Curtain (red guillotine with center part)

Dead hung portal set 1’ 6”  Electric borders at 3’ 3”; 11’ 10”; 18’ 6” and 24’ 1”

Movie Screen 8’ 6” (all non-movable)

Deck:     

Hardwood Front, Softwood Rear Floor

Lags allowed.

Trap in upstage center floor on sectional grid

Stage Masking:   

Flat black velour masking consists of:

Black portal set that masks stage opening down to 30’ wide by

18’ high

Four sets of legs 15’ wide by 33’ high

Four borders 60’ wide by 15’ high

Rear black backdrop60’ wide by 32’ high (2 sections)

Platforms:

Various risers used by orchestra.

Conductor’s podium available.

Wardrobe:         

Located in basement.  Access via trap in stage floor or stairs on each side of stage.  Coin operated washer and dryer.

Dressing Rooms:

One star room; bath and shower - stage left at stage level

One multi-purpose chorus room next door.

Two small rooms (one each on second and third floors stage left)

Four chorus rooms, two each on second and third floors on stage left.  Each level has bath and shower facilities.

Sound:

No house console, no house intercom system.

Overhead speaker cluster and under balcony delay speakers.

Paging System to dressing rooms available.

FM transmitter for hearing impaired use.

FOR ALL EVENTS:

Overhead cluster and under balcony delay speakers must be used  with your system.

Separate or twofer XLR tie in for cluster and under balcony speakers.

Road console may be located in house right rear (rows FF and GG) Ten seats required to be removed.

Cable run from stage is 110’.

Rehearsal Space:

None

Storage:

None

Loading Door:

Upstage Right Back Wall. 

Height’ 9’ Width 8’.

Loading door is at street level which is 13’ above stage level.

There is a block and tackle with an electrical mule

(capacity 2,000 lb). Tractor Trailers may park on sidewalk behind the stage house to load and unload. 

 